Release Notes
4.2
CAPA
This release is not backwards compatible and requires firmware with version 4.7 or higher. Please use the Firmware Updater to update the firmware.
- New and updated features
- An estimation figure of the ongoing 3D print is shown, 3D live view
- Collision checker
- When there is a collided file, a button will appear on the list item. The user can click on it to get a dialog showing the items that the file collides with.
-
Bug fixes
- Movement in the
Navigation Tool
will be blocked while drop or pick procedure is in progress - The
Choose Probe
phase of thePrepare System
workflow is repeated only if the probe was dropped
- Movement in the
-
Other
- 3D view dialog box is improved
- The help lines on the video feed are always present during gripping
- Dynamic content height. The content height depends on the height of the printed structures
- The Print History files can be stored. The data from print history will be stored separately for every user
- The version number is presented in the top left corner
4.1
CAPA
This release is not backwards compatible and requires firmware with version 4.6 or higher. Please use the Firmware Updater to update the firmware.
- New and updated features
- A separate tool called
Print History
(it is placed in the bottom-left corner)- The processed print files are present there
- Offset measurement (
3D Printing calibration
) is made possible through this tool
3D Printing
workflow is changed- While a 3D print is in progress, the files that are not currently being processed can be deleted
- Processed printfiles are moved from the
3D Printing
workflow to thePrint History
tool
- The camera settings are automatically changed on entering and leaving the
Fill Probe
part of thePrepare System
workflow - Parameters in
3D Printing
andMapping
workflows are changed - When the user tries to perform a movement while the stage is not initialized, a popup will be shown that will guide the user towards stage initialization
- Visual changes in the status bar
- A separate tool called
- Bug fixes
- Scrolling problem in the
3D Printing
workflow - While a crosshair is present and dragged, the photo that is shown on the inside of it is updated over time.
- In the
Navigation Tool
, the points that are not in the boundaries of our movement capabilities will not be available for picking
- Scrolling problem in the
- Other
- Maintenance schedule is updated to better suiting intervals
3D Printing Calibration
workflow is removed- The PostgreSQL database is not required by CAPA anymore
- The user can turn on/off maintenance mode from the bot settings in CAPA
- The Print log is expanded, the type of the ionink used and the deposition potential are added
4.0.2
CAPA
This release is not backwards compatible and requires a firmware with version 4.4. Please use the Firmware Updater to update the firmware.
-
New features
- Potentiostat tool
- Cell regulation toggle button on the
Initialize System
pop-up - Cell regulation toggle button on the
Application Exit
pop-up Head nose wash
workflow- Accessible area in the navigation tool
- Toggle camera button in the navigation tool
- Preparation workflows added:
Prepare Printing Chamber
andPrepare Probe
- Bottom (green ellipse) and top camera (blue ellipse) are presented in the navigation tool
-
Bug fixes
- Visible range in the oscillator is always shown
-
Other
- In the left port, only probe plate and well plates are available for loading. In the right port, only calibration plate and printing chambers are available for loading.
- Error handling is improved in the
Calibrate XY (Stage)
andCalibrate XY (Head)
workflow - In the
Calibrate XY (Stage)
workflow, after moving to the reference position, the probe will be set to content height - Movements while aligning laser are limited from 1 to 1000 micrometers
- After the mapping is done, the probe is retracted by safety retract distance
- After automatically maximising the signals (in the
Prepare System
workflow) the signals will be presented in different colours - Dragging is disabled in some parts of the the
Calibrate Pixel Size
workflow - No-go area is activated when the
Mapping
workflow starts - For running CAPA 4.0, .NET 5 must be installed (if not already present)
- The probe is fully retracted when the wash is aborted (in the
Head Nose Wash
workflow) - If the wash tool is closed while a wash procedure is in progress, the wash procedure will be aborted (it will not run in the background)
- New parameters are added (in the
3D Printing
,3D Calibration
,Mapping
workflows) and the parameters are split in: parameters and advanced parameters - The items from the postgres database will be transfered to a new XML database and deleted
3.3.1
CAPA
This release is not backwards compatible and requires a firmware with version 4.0. Please use the Firmware Updater to update the firmware.
-
New features
- A warning is presented in case a specified number of days have passed since the last rail lubrication
- An option to only drop the probe is available
-
Bug fixes
- In the
Calibrate pixel size
workflow, the magnification cannot be set manually to zero - The
Calibrate pixel size
workflow cannot be completed if а lens is not selected - The plate editor can only create plates with features on them that are in the full range of the probe
- In case the default plates are not present, the first available plates will be presented as default ones
- During the
Stage Calibration (XY) (fine)
workflow, the offset is inverted (made in the correct direction) - Better error messaging is presented when the system is trying to move out of scope
- Possible deadlocks during start-up and shutdown are removed
- The zoom function does not affect the calculations during the
Calibrate pixel size
workflow
- In the
-
Other
- The description of the status during the printing is improved
- Extended error handling while gripping or dropping a probe
- In the
Prepare System
workflow, the configuration of the probe cannot be completed if local specifications about the probe are not downloaded, or if local ones are not selected - Bigger cursors on the video feed have been added
- In case the Bot fails to initialize, a dialog box enabling you to close the app will appear
3.2.0
CAPA
This release is not backwards compatible and requires a firmware with version 4.0. Please use the Firmware Updater to update the firmware.
-
Removed features
- Conversion options for deflection
- Calibration offset has been replaced with internal probe offset
- Relative positioning in navigation tool
-
Bug fixes
- Activate result history list button initially
- Correctly show print file preview
RecordLogFiles
option in 3DP workflows targets all log files, not just deflection log- Tell user to go to a well instead of a sample in
Go to Well
action inPrepare System
workflow - Shutdown components that failed their initialization and free their resources
- This resolves the issue which caused CAPA to hang during a shutdown
- Always show correct probe plates in
Calibrate Z (Height)
workflow - Ensure same time stamp for all files related to the same print job
-
Other
- Extend idle pressure range to ± 20 mbar
- Use system-wide idle pressure for 3D printing
- Reconnect with pressure controller when an error occurs
- Show warning if there are pending Windows updates
- Update
3D Printing workflow
UI - Update
3D Printing Calibration
workflow UI - Update
Measure Angle
workflow UI - Use printing logic in
Mapping
workflow for faster maps - Add conditional OK buttons to 3D Printing workflows
- Allow changing of printing parameters while print run is paused
- Introduced new printing parameter to change the voxel retract height
- Updated the print properties log to V2 to include the voxel retract height
- Persist maintenance parameters directly through CAPA
- Add more verbose logging for IDS cameras
- Tell users to reboot when
E_COMM_SETUP
error occurs - Add new maintenance workflow
Stage Calibration (XY) (fine)
to fine-tune the stage calibration - Persist probe offset as a global setting
- Reduce well size of 12-Well Plate by 1mm
- Adjust 3D printing parameter ranges
- Allow users to specify the name of the output file of the Mapping workflow
- Restore the initial stage position after mapping
- Rename
Online Documentation
toCERES Printer Manual
MATLAB apps
The MATLAB apps now require MATLAB 2020a to run.